SOLAR ALARM WITH FLASHING LIGHT – KAH09

SOLAR ALARM WITH FLASHING LIGHT – KAH09

with oil sensor

image du SOLAR ALARM WITH FLASHING LIGHT – KAH09

Autonomous oil level control device for oil separators

Avantages :

  • Compliance: the KAH09 level alarm has been specially designed to detect a water/oil interface in an oil separator in accordance with standard EN 858
  • Secure, optimized operation: the KAH09 alarm system enables: - alerting the operator in case of device saturation, with the triggering of the flashing light - limiting maintenance frequency and pumping costs
  • Adaptability: the KAH09 alarm box can accommodate up to 2 probes, and is supplied with a hydrocarbon probe including 5 ml of cable and a cable extender for zone 0
  • Autonomy: autonomous system with battery powered by a solar panel

En bref

En détails

Dimensionnement

En pratique

Taille :

Application :

The KAH09 solar oil alarm is an ATEX device associated with pre-treatment devices (decanters and oil separators) which ensures optimum operation of the appliance by means of a level control system.

Conception :

  • IP 65 polycarbonate enclosure for wall or floor mounting (optional). Dimensions (WxHxD): 200 x 400 x 132 mm
  • ATEX certification: control unit II (1) G [Ex ia] II B for installation in non-hazardous areas, combined with VTT 09 ATEX 027X certified hydrocarbon sensor for installation in Zone 0
  • Model suitable for ambient temperatures from -30°C to +60°C, with 12V and 7 Ah lead-acid battery
  • Alarm indication by activation of the flashing light, which flashes every 5 seconds until the alarm stops
  • The KAH09 alarm measures the status of the oil detection probe every hour, thus allowing great autonomy of the alarm for more than 10 days, including with the triggering of the flashing light

Fonctionnement :

The KAH09 alarm system triggers a flashing light as soon as the oil layer in the separator reaches the upper part of the probe. The alarm signals when it is necessary to drain or clean the separator. The KAH09 alarm must be installed outside the ATEX zone. Only the oil probe is designed to be in zone 0. The installation is energy independent with a battery powered by a solar panel.

Options :

  • Additional oil probe - SEP0208L
  • Additional sludge level probe - SEP0205L
  • Additional high level probe - SEP0206L
  • Enclosure support - SEP1100L
  • Installation and commissioning - MO020
Référence TN Débit de pointe (l/s) Vol. utile (L) Vol. débourb. (L) Vol. hydro (L) Diamètre (mm) L (mm) H (mm) DN FEE (mm) FES (mm) Poids (kg)
SP1HDO2003KA 20 100 3460 2000 200 1600 3100 1700 315 700 750 570
SP1HDO2503KA 25 100 4600 2500 250 1600 3750 1700 315 700 750 670